Maccor's 3600/3650 primary battery test system is specifically designed for primary battery testing and is applicable to ANSI and IEC standards.
Performance characteristics:
Each test channel in the system is completely independent and controllable.
Test mode can be programmed as required for constant current mode, constant power mode, constant resistance mode, constant voltage mode.
The test procedure can be transferred to any other test step according to the end condition.
The test end conditions include various rated values (voltage, current, time, etc.) and integral values (energy, capacitance, half cycle data).
Each test program has four nested loops that can be applied, and common test programs can be called as subroutines.
The test system can display, depict and print test data or complete test process in real time.
Maccor's data analysis software package MIMS can draw the test data graph, and can automatically transmit the test data to the central data processing server through the local area network, so as to analyze and count the test situation.
Through Maccor's data analysis software, charts can be edited by users and can define coordinates, line colors and many more parameters.
For the user needs commonly used graphics can be stored as a template, easy to reuse later.
Data from multiple test channels can be plotted on one graph, or multiple graphs can be edited into one view.
The test system can be calibrated once a year according to NIST standards.
Specifications:
Current range: 1mA-2500mA, divided into 4 measuring segments 1mA, 15mA, 200mA, 2500mA
Voltage range: 0-5V, accuracy/-1 mV
Voltage accuracy: 0.02%FS
Minimum discharge: 0.2V or 0.35 * current
Operation mode: constant current, constant voltage, constant power, constant resistance
Minimum time step: 500mS, time resolution 50mS
Previous Page
Next Page
Related Products
S4000 Series High Precision Battery Test System
S4000C Series High Precision Battery Test System
S6000 Series High-precision Primary Cell Test System
M4300 High Precision Desktop Battery Tester
M4200 high precision desktop battery tester
Domestic assembly of MC8, MC16 desktop battery tester
Message consultation